1. Monitor udder health regularly
- Check udder health regularly: first check fresh first-calf heifers and cows 1-2 weeks after calving using California Mastitis Test, Cell Counter, DHIA milk records, etc
- Regularly review the dairy processor info on milk quality
- Keep record of udder health results for each cow
- Always keep milk of identified sick cows separate
- First start with milking healthy cows and first-calf heifers
- Next milk fresh cows and first-calf heifers until they are checked for udder health status
- Milk older cows, cows cultured positive for contagious pathogens, and sick cows last or in separate group
- Never strip milk onto the florr
- Strip 2-3 milk jets from each teat into a foremilk or strip cup
- Examine the milk for flocculation, color change, or other inconsistencies
- Foremilking also stimulates milk let-down
- Clean each teat and teat end using an approved pre-milking teat cleaner
- Wait 30 seconds before removing pre-milking teat cleaner
- Use disposable paper towel or udder towels to clean and carefully dry each teat properly
- Never use towels for more than one cow
- At the start of each milking
- Ensure vacuum level, pulsation rate, and pulsator ratio are within recommendations of parlor manufactor
- Attach milking cluster within 60 seconds of teat preparation
- Avoid air entry during cluster attachment
- Check cluster positioning
- Make sure long milk tubes are aligned with pulse tube, avoiding twisting of tubes
- Clean and disinfect clusters in between cows
- Watch the milking process during milking
- Over milking can damage teat ends
- Identify the end of milking by direct observation of milk flow or via flow sensors in the case of automatic cluster removal
- Shut off vacuum to the cluster when milking is completed
- Allow claw vacuum to decline fully before removing cluster
- Do not squeeze the udder
- Take off cluster after the vacuum shut-off
- Use an approved post-milking teat disinfectant as this is the mist effective way to prevent the spread of mastitis
- Dip or spray teats as soon as the milking cluster has been removed
- Keep the cows standing for 30 minutes after milking
- After each milking rinse and clean internal milking system
- Clean the outside of milking units and all surfaces in the parlor
- Disinfect the milking system using approved sanitizers following label instructions
- Always check temperatures to ensure correct cooling is reached during and after milking
- Milk cooling and storage tanks need to be cleaned immediately after emptying
- Review milk processor info on milk quality and milk composition regularly
- If available, cross check with data from udder health assessments
- Regular preventative maintenance including replacement of liners, tubes, and other parts is the best way to ensure a well functioning milking system
No comments:
Post a Comment